SolarEdge
ESS Energy Storage Solution (MWh Container)
With the cutting-edge design technique of material engineering, the SolarEdge pouch cell possesses a better heat dissipation compared with other traditional metal shell-coated cells, and have the advantage of high energy density, loading and safety. It is suitable for power type frequency regulation, energy peak load shaving, renewable energy smoothing and many other applications.
SolarEdge ESS Battery Solutions
10ft Container
Model | KCN069711DF26AAA0 | Remark | ||
---|---|---|---|---|
Configuration | System | 1 battery control cabinet | Incl. 1EA BCP per Bank | |
Bank | 4 battery arrays in parallel | 660.6kWh | ||
Rack | 12 modules in series | 165.1kWh | ||
Module | 2P22S | 13.7kWh | ||
Cell | high power | 85Ah / KCL255085PN0 | ||
Installed Energy (kWh) | 660.6 | |||
Usable Energy (kWh) | 607.7 | @ 1P discharge, BOL | ||
Nominal Voltage (Vdc) | 971.5 | |||
Operating Voltage Range (Vdc) | 844.8 ~ 1,090.3 | |||
Power (kW) | Charging | rated | 660.6 | 1P |
max | 1,915.8 | 2.9P | ||
Discharging | rated | 660.6 | 1P | |
max | 1,915.8 | 2.9P | ||
peak | 3,303.1 | 5P, <10 seconds. From SOC ≥50% | ||
Current (A) | Charging | rated | 680 | 1C |
max | 1,972 | 2.9C | ||
Discharging | rated | 680 | 1C | |
max | 1,972 | 2.9C | ||
peak | 3,400 | 5°C, <10 seconds. From SOC ≥50% | ||
Dimensions (WxLxHm) | 2.7×3×3.2 | |||
Weight (Approx.ton) | 11.2 | ± 10% | ||
IP Grade | 54 | |||
Cycle Life at 90% DOD | ≥6,000 cycles | @25±3℃, 1C/1C, SOH 70% | ||
Cycle Life at 80% DOD | ≥8,000 cycles | @25±3℃, 1C/1C, SOH 70% | ||
Certification | UN 38.3、UL 1642、UL 1973、IEC 62619、UL 9540A | Cell level | ||
UN 38.3、EC、IEC 62619 | Module level | |||
CE、IEC 62619 | Rack level | |||
N/A | Container level | |||
Compliance | RoHS II and REACH |
* Our company is not responsible for any omissions, misstatements or non-factual statements (whether express or implied) in this product specification, please contact us for further information.
* Product images are for reference only, actual products may vary.
20ft Container
Model | KCN169711JF26AAA0 | Remark | ||
---|---|---|---|---|
Configuration | System | 1 battery control cabinet | Incl. 1EA BCP per Bank | |
Bank | 10 battery arrays in parallel | 1651.5kWh | ||
Rack | 12 modules in series | 165.1kWh | ||
Module | 2P22S | 13.7kWh | ||
Cell | high power | 85Ah / KCL255085PN0 | ||
Installed Energy (kWh) | 1,651.50 | |||
Usable Energy (kWh) | 1,519.40 | @ 1P discharge, BOL | ||
Nominal Voltage (Vdc) | 971.5 | |||
Operating Voltage Range (Vdc) | 844.8 ~ 1,090.3 | |||
Power (kW) | Charging | rated | 1,651.5 | 1P |
max | 3,369.2 | 2.04P | ||
Discharging | rated | 1,651.5 | 1P | |
max | 3,369.2 | 2.04P | ||
peak | 4,624.4 | 2.8P, ≤20 minutes. | ||
Current (A) | Charging | rated | 1,700 | 1C |
max | 3,468 | 2.04C | ||
Discharging | rated | 1,700 | 1C | |
max | 3,468 | 2.04C | ||
peak | 4,800 | 2.8℃, ≤20 minutes. | ||
Dimensions (WxLxHm) | 2.7 x 6.0 x 3.2 | |||
Weight (Approx.ton) | 23.3 | ± 10% | ||
IP Grade | 54 | |||
Cycle Life at 90% DOD | ≥6,000 cycles | @25±3℃, 1C/1C, SOH 70% | ||
Cycle Life at 80% DOD | ≥8,000 cycles | |||
Certification | UN 38.3、UL 1642、UL 1973、IEC 62619、UL 9540A | Cell level | ||
UN 38.3、EC、IEC 62619 | Module level | |||
CE、IEC 62619 | Rack level | |||
N/A | Container level | |||
Compliance | RoHS II and REACH |
* Our company is not responsible for any omissions, misstatements or non-factual statements (whether express or implied) in this product specification, please contact us for further information.
* Product images are for reference only, actual products may vary.
40ft Container
Model | KCN529712MF26AAB0 | Remark | ||
---|---|---|---|---|
Configuration | System | 2 battery control cabinet | Incl. 1EA BCP per Bank | |
Bank | 13 battery arrays in parallel | 2,601.7kWh | ||
Rack | 12 modules in series | 200.1kWh | ||
Module | 2P22S | 16.6kWh | ||
Cell | high energy | 103Ah / KCL255103EN0 | ||
Installed Energy (kWh) | 5,203.40 | |||
Usable Energy (kWh) | 4,787.10 | @0.5P discharge, BOL | ||
Nominal Voltage (Vdc) | 971.5 | |||
Operating Voltage Range (Vdc) | 844.8 ~ 1,090.3 | |||
Power (kW) | Charging | rated | 2,601.7 | 0.5P |
max | 5,203.4 | 1P | ||
Discharging | rated | 2,601.7 | 0.5P | |
max | 5,203.4 | 1P | ||
peak | 8,273.4 | 1.59P, ≤20 minutes. ≥SOC 85% | ||
Current (A) | Charging | rated | 2,678 | 0.5C |
max | 5,356 | 1C | ||
Discharging | rated | 2,678 | 0.5C | |
max | 5,356 | 1C | ||
peak | 9,600 | 1.79℃, ≤20 minutes. ≥SOC 85% | ||
Dimensions (WxLxHm) | 2.7 x 12.1 x 3.2 | |||
Weight (Approx.ton) | 56 | ± 10% | ||
IP Grade | 54 | |||
Cycle Life at 90% DOD | ≥6,000 cycles | @25±3℃, 1C/1C, SOH 70% | ||
Cycle Life at 80% DOD | ≥8,000 cycles | @25±3℃, 1C/1C, SOH 70% | ||
Certification | UN 38.3、UL 1642、UL 1973、IEC 62619、UL 9540A | Cell level | ||
UN 38.3、EC、IEC 62619 | Module level | |||
CE、IEC 62619 | Rack level | |||
IEC 62933-5-1 | Container level | |||
Compliance | RoHS II and REACH |
* Our company is not responsible for any omissions, misstatements or non-factual statements (whether express or implied) in this product specification, please contact us for further information.
* Product images are for reference only, actual products may vary.
Product Features
Cost Effective
with High Energy Density
SolarEdge's containerized battery solution can be discharged at a high C-rate. This feature enables the KCN to be installed in the area with limited space due to its compact space occupied and it can be utilized for multiple purposes (e.g. frequency regulation + ramp rate control). By utilizing high energy type cells, the KCN can also be customized to store very large amounts of energy within a limited space.
Convenience of
Expanding Capacity
SolarEdge's containerized battery solution is composed of SolarEdge’s Battery Modules and SolarEdge’s Battery Racks with fast and easy connectivity (in series/parallel). The option of parallel connection allows the customer to easily increase the energy capacity while maintaining the same system voltage. For the service status of critical mission, containerized systems can remain operating while allowing the replacement of modules within racks without interruption.
Voltage Stability
and Power Security
SolarEdge's containerized battery solution is an optimal solution to maintain a stable voltage and it also provides backup power capabilities for numerous applications such as power transmission, electricity generation, etc. SolarEdge's system-level Battery Management System (BMS) provides a new paradigm in the energy industry. The BMS can elevate the financial value of the ESS and facilitate its application to an electric power supply, power backup system, renewable energy integration, etc. SolarEdge's containerized battery solution's key role is to stabilize the power grid for large scale systems interconnected with PV and Wind power.
Energy Storage Container Infrastructure
SolarEdge Containerized Energy Storage can be used in various applications, such as peak load shaving, frequency regulation, renewable energy storage, micro-grid and UPS. In 10ft / 20ft / 40ft mobile containers with ISO certification, you can also install a battery capacity of 250kWh-5MWh.

Cooling and Air Conditioning System
Other Company HVAC System
Ambient Cooling System

The ambient conditions of battery containers are usually controlled by 5~6 HVAC units that control the environmental conditions of the entire 40 ft container.
Cons
- A huge amount of energy is required to cool the entire container
- Very difficult to concentrate cooling where heat is produced
- Ambient temperature affects cooling in the container
SolarEdge HVAC System
Direct Cooling System

The systems use SolarEdge's battery container, which features a direct cooling design in which the container's Heating Ventilation and Air Conditioning(HVAC) system only regulates temperatures inside the system's racks (1/6 of entire container volume) rather than the entire container. This results in 70 percent fewer air conditioning auxiliary loads than standard containers.
The Direct Cooling System connects SolarEdge Racks to the HVAC system via an air duct so the cool air can reach the heat source directly.
Pros
- The cooling effect is almost immediate and very efficient
- Ambient conditions do not affect the operation
Introduction to Battery Array
Customized Requirements
- Life expectancy up to 8,000 Cycles (@ 80% DoD, 25±3°C, 1C/1C, SOH 70%) *Cycle life may vary with the battery type.
- Customized pre-sales and after-sales technical services
Installation Performance Case
- The shipment and installation of ESS high-power and large-scale energy storage systems exceeded 413MW, with a total of 85 cases in 35 countries, including Australia, Germany, South Korea, the United States, Singapore, Hong Kong, etc.

High Power
Thing | Specification | Remark | ||||
---|---|---|---|---|---|---|
dReg 0.5 | dReg 0.5 | dReg 0.25 | dReg 0.5 | dReg 0.25 | ||
System Configuration | 1 battery control cabinet | 1 battery control cabinet | 1 battery control cabinet | 2 battery control cabinet | 2 battery control cabinet | Bank |
Battery Configuration | 4 battery arrays (2C6R) | 10 battery arrays (2C6R) | 12 battery arrays (2C6R) | 20 battery arrays (2C6R) | 24 cell arrays (2C6R) | in parallel |
Install Power | 660kWh | 1,652kWh | 1,980kWh | 3,303kWh | 3,960Wh | |
Standard Voltage | 971.5Vdc | 971.5Vdc | 971.5Vdc | 971.5Vdc | 971.5Vdc | |
Operating Voltage Range | 844.8-1090.3Vdc | 844.8-1090.3Vdc | 844.8-1090.3Vdc | 844.8-1090.3Vdc | 844.8-1090.3Vdc | |
Maximum Charging Power | 165.1kW (1P) | 165.1kW (1P) | 165.1kW (1P) | 165.1kW (1P) | 165.1kW (1P) | 149.4kWh @ 1P discharge, BOL |
Peak Discharge Power | 825.7kW | 825.7kW | 825.7kW | 825.7kW | 825.7kW | 5P, ≤10 sec. from SOC ≥50% |
Maximum Discharge Power | 478.9kW | 478.9kW | 478.9kW | 478.9kW | 478.9kW | 2.9P |
DC to AC Conversion Efficiency | > 95% | > 95% | > 95% | > 95% | > 95% | @ 1.0P,BOL |
Range of Working Temperature | Charge: 0~10℃@<0.2P, 10~35℃@<2.9P, 35~45℃@<1P/Discharge: 0~55℃ | Charge: 0~10℃@<0.2P, 10~35℃@<2.9P, 35~45℃@<1P/Discharge: 0~55℃ | Charge: 0~10℃@<0.2P, 10~35℃@<2.9P, 35~45℃@<1P/Discharge: 0~55℃ | Charge: 0~10℃@<0.2P, 10~35℃@<2.9P, 35~45℃@<1P/Discharge: 0~55℃ | Charge: 0~10℃@<0.2P, 10~35℃@<2.9P, 35~45℃@<1P/Discharge: 0~55℃ | suggested value |
Container Type | 10 feet*1 | 20 feet*1 | 20 feet*1 | 40 feet*1 | 40 feet*1 | |
Warranty Period | 10 years for batteries, 5 years for air-conditioning and fire-fighting facilities in the container | 10 years for batteries, 5 years for air-conditioning and fire-fighting facilities in the container | 10 years for batteries, 5 years for air-conditioning and fire-fighting facilities in the container | 10 years for batteries, 5 years for air-conditioning and fire-fighting facilities in the container | 10 years for batteries, 5 years for air-conditioning and fire-fighting facilities in the container |
* Our company is not responsible for any omissions, misstatements or non-factual statements (whether express or implied) in this product specification, please contact us for further information.
* Product images are for reference only, actual products may vary.
High Energy
Thing | Specification | Remark | ||||
---|---|---|---|---|---|---|
System Configuration | 1 battery control cabinet | 1 battery control cabinet | 1 battery control cabinet | 2 battery control cabinet | 2 battery control cabinet | Bank |
Battery Configuration | 4 battery arrays (2C6R) | 10 battery arrays (2C6R) | 12 battery arrays (2C6R) | 20 battery arrays (2C6R) | 24 cell arrays (2C6R) | in parallel |
Install Power | 800kWh | 2,000kWh | 2,400kWh | 4,000kWh | 4,800kWh | |
Standard Voltage | 971.5Vdc | 971.5Vdc | 971.5Vdc | 971.5Vdc | 971.5Vdc | |
Operating Voltage Range | 884.4-1,090.3Vdc | 884.4-1,090.3Vdc | 884.4-1,090.3Vdc | 884.4-1,090.3Vdc | 884.4-1,090.3Vdc | |
Maximum Charging Power | 200.1kW (1P) | 200.1kW (1P) | 200.1kW (1P) | 200.1kW (1P) | 200.1kW (1P) | 178.1kWh @ 1P discharge, BOL |
Peak Discharge Power | 6000.3kW | 6000.3kW | 6000.3kW | 6000.3kW | 6000.3kW | 3P, ≤10 sec. from SOC ≥50% |
Maximum Discharge Power | 400.2kW | 400.2kW | 400.2kW | 400.2kW | 400.2kW | 2P |
DC to AC Conversion Efficiency | > 95% | > 95% | > 95% | > 95% | > 95% | @ 0.5P, BOL |
Range of Working Temperature | Charge: 0~10℃@<0.2P, 10~35℃@<1P, 35~45℃@<0.5P/Discharge: 0~55℃ | Charge: 0~10℃@<0.2P, 10~35℃@<1P, 35~45℃@<0.5P/Discharge: 0~55℃ | Charge: 0~10℃@<0.2P, 10~35℃@<1P, 35~45℃@<0.5P/Discharge: 0~55℃ | Charge: 0~10℃@<0.2P, 10~35℃@<1P, 35~45℃@<0.5P/Discharge: 0~55℃ | Charge: 0~10℃@<0.2P, 10~35℃@<1P, 35~45℃@<0.5P/Discharge: 0~55℃ | suggested value |
Container Type | 10 feet*1 | 20 feet*1 | 20 feet*1 | 40 feet*1 | 40 feet*1 | |
Warranty Period | 10 years for batteries, 5 years for air-conditioning and fire-fighting facilities in the container | 10 years for batteries, 5 years for air-conditioning and fire-fighting facilities in the container | 10 years for batteries, 5 years for air-conditioning and fire-fighting facilities in the container | 10 years for batteries, 5 years for air-conditioning and fire-fighting facilities in the container | 10 years for batteries, 5 years for air-conditioning and fire-fighting facilities in the container |
* Our company is not responsible for any omissions, misstatements or non-factual statements (whether express or implied) in this product specification, please contact us for further information.
* Product images are for reference only, actual products may vary.
BCP (Battery Connection Panel)
BMS Battery Management System
- Processes and displays real-time status of the battery system from the rack level down to the cell level(up to 30 racks)
- Provides data on energy, voltage, current, SOH/SOC status and easier access to data through user-friendly GUI
- Anomalies identifiable at the cell and module level for quick diagnosis
- Activates various protection mechanisms during emergency situations
- Monitoring data and event log saved up to 3 years
- Remote Management feature available over Ethernet
BMS monitoring screen (optional)
DC panel
- Fuse and circuit breaker designed to protect the battery system against short circuit
- Fuse and circuit breaker status available through HMI
Machine Features
- Galvanic isolation (prevent the electricity from circuiting through each battery rack)
- Easy maintenance
- Communication to PCS or EMS with CAN/ MODBUS
- Integrated HVAC
Scalable over 10MWh
Due to the high energy density of SolarEdge’s superior lithium polymer battery, the KCN can store more energy in a limited space than any other battery storage system. The KCN can be connected in parallel to increase the total energy available over 10MWh.
KEY STRENGTHS
- High Power and High Energy charge/discharge
- Modularity and Scalability
- Optimal Temperature Control and Safety
APPLICATIONS
- Frequency regulation and Spinning Reserve
- Energy Storage System for EV charging Stations
- Improving the power quality and reliability of renewable energy
- Peak Load Management
- Arbitrage
- Voltage Support
- T&D deferral